Val-de-Grâce

Context

As part of a project to renovate and extend the former Val-de-Grâce Hospital in Paris, CIDECO was commissioned to carry out a diagnosis of the reinforced concrete structures and secondary works of the building.

Operations

  • Survey of pathologies affecting the structural elements
  • Inspection of façades and roofing conditions
  • Identification of roof waterproofing system composition
  • Verification of compliance of staircases and guardrails
  • Assessment of interior joinery and partition systems
  • Characterization of reinforced concrete using GPR, rebound hammer, and localized destructive testing
  • Core sampling for compressive strength and carbonation depth testing
  • Metal sampling for tensile strength analysis
  • Determination of foundation geometry
  • Calculation of the load-bearing capacity of horizontal and vertical members
  • Assessment of fire resistance
  • Recommendations for structural rehabilitation works

Key figures

12
levels
22
rebound hammer tests
50
localized destructive samplings
7
concrete cores with compressive tests
15
tensile tests on metal samples
54
GPR scans